We manufacture and supply three-phase transformers. Please feel free to contact us. Click the button for a quick reply.
Three-Phase Transformer
A three-phase transformer is used in three-phase AC power systems. Through electromagnetic induction, it converts three-phase AC voltage from one level to another while keeping the frequency unchanged. The primary windings produce magnetic flux in the core, and the secondary windings induce a three-phase EMF. The turns ratio determines step-up or step-down
| Item | Specification |
|---|---|
| Model | 1.5KVA-100KVA |
| Response speed | 10ms |
| Adjustment speed | 100V/S |
| Circuit Method | IGBT / PWM Modulation |
| Output waveform | Standard sine wave CF=1.4 |
| Output Current | Phase Current High Grade 41A Low Grade 82A |
| Frequency stabilization | ≤0.01% |
| Load Voltage Stabilization | ≤1% |
| Waveform Distortion | ≤2% (pure resistive load) |
| Phase Angle | 120°±1° |
| Crest factor ratio | 31 |
| Protection reaction time | ≤2ms |
| Efficiency | ≥97% |
Comparison between Dry-Type Transformers and Oil-Immersed Transformers
| Item | Dry-Type Transformer | Oil-Immersed Transformer |
|---|---|---|
| Insulation/Cooling Medium | Air, epoxy resin, etc., oil-free | Transformer oil; oil provides both insulation and cooling |
| Safety | Fireproof, explosion-proof, no oil leakage, high safety | Risk of oil leakage, fire, and explosion |
| Heat Dissipation | Relatively poor; relies on natural air cooling or fans | Good; oil circulation cooling, suitable for large capacity |
| Capacity and Voltage | Generally smaller, commonly 35 kV and below | Can be made with large capacity and high voltage |
| Overload Capability | Relatively weak | Relatively strong |
| Maintenance | Simple maintenance, basically maintenance-free | Requires regular checks of oil quality and oil level; higher maintenance workload |
| Cost | Relatively high manufacturing cost | Relatively lower |
| Installation Environment | Suitable for indoor use, high-rise buildings, subways, commercial centers | Suitable for outdoor substations, industrial and mining enterprises |
| Noise | Relatively high (fan/core) | Relatively low |
| Environmental Impact | No risk of oil pollution | Oil leakage may pollute the environment |
| Simple Summary: | ||
| For large capacity, outdoor use, low cost, and strong overload capability → choose an oil-immersed transformer | ||
| For safety, indoor use, and low maintenance → choose a dry-type transformer. For safety, indoor use, and low maintenance → choose a dry-type transformer. |
Our Three Phase Transformer Workshop
Our 13,000 ㎡ three phase transformer workshop runs 25 production lines, supported by a mold center, product testing lab, and dedicated workshops for winding, assembly, sheet metal work, and aging tests. With 200 team members, including 32 technical engineers, we achieve a daily output of over 1,000 voltage stabilizers.
Welcome to our YouTube channel for a deep tour. If you want to come for a visit, please feel free to contact us.










Three Phase Transformer Packing & Shipment
- Three phase transformersare packed in shockproof, moisture-proof, and rust-proof export packaging. Small units use reinforced cartons; large industrial models adopt IPPC heat-treated wooden crates or pallets. Machines include corner buffers, insulated terminals, and desiccants to prevent condensation and corrosion. Outer boxes are marked with Fragile, This Side Up, Keep Dry and clear shipping marks.
- Air Freight: Complies with IATA rules. Terminals are insulated, and loose metal parts are secured.
- Sea Freight: Enhanced protection against salt spray. Solid wood packaging must carry valid IPPC marks to avoid quarantine detention.
Contact Us
We’d love to hear from you! Please send us a message using the form now. We will contact you within one working day. Please watch for emails from addresses ending in “@kesunme.com.”
FAQ
The primary three-phase windings are connected to a three-phase supply and produce a rotating magnetic flux in the core. The secondary windings then induce a three-phase voltage. The voltage ratio is determined by the turns ratio between the primary and secondary windings.
Common types include dry-type transformers, oil-immersed transformers, distribution transformers, power transformers, isolation transformers, and autotransformers. They can also be classified by connection group, such as Yyn0, Dyn11, and YNd11.
They are widely used in power plants, substations, industrial plants, commercial buildings, data centers, hospitals, airports, railways, renewable energy systems, and other three-phase power distribution and transmission applications.
Consider rated capacity (kVA), primary and secondary voltage, frequency, connection group, cooling method (dry-type or oil-immersed), installation environment, load type, overload capability, efficiency, and certification requirements. The correct choice ensures safe, reliable, and efficient operation.